4 glazing in unframed side hinged swinging doors.
Safety glass internal doors regulations.
As the drawing below shows any glass in doors that does not start over 1500mm from the floor must be safety glass.
Bathrooms for all areas up to 2 metres high door side panels if less than 300mm away from the door and positioned 1200mm or less above the floor around stairs for a distance of 1000mm from either side of the stairs and 2000mm from the bottom of the stairs.
Certain types of transparent plastic sheet can satisfy the impact requirements for safety glass.
As a general guide you must use safety glass in.
Within any glazed door up to 1500mm from floor level.
The construction products regulations 2013 cover glazing.
Except as provided in paragraph d of this section the following locations and areas require the use of safety glazing conforming to the requirements of paragraph c of this section.
Internal doors with glass panel doors flush doors.
In addition any glass located adjacent to a door within a 24 inch arc of the door must be constructed from safety glass if the bottom edge of the glass is less than 60 inches above the walking.
Glass in doors and side panels may only be glazed in class c materials where the smaller dimension is a maximum of 900mm.
1 glazing in all entrance or exit doors.
The shaded areas shown in the diagram below show critical locations where toughened safety glass will be required.
The glass units in windows will have to be toughened if the lowest part of the window is 800mm from the floor.
At least 0 33 square metres and at least 450mm high and 450mm wide.
Often this means that the glass will be toughened safety glass that s designed to prevent dangerous shards being produced if the glass is ever.
2 glazing in fixed and sliding panels of sliding glass doors.
Any glass used in doors or used adjacent to a door such as sidelights must comply with the approved document n of the building regulations 1991.
Any glazing in a door that is less than 1500mm from the floor or within 300mm either side of a door.
All glass units for doors must be toughened as windows that are connected to doors side panels and flag windows.
3 glazing in storm type doors.
This means that the glass must be approved safety glass.
If you are buying replacement glazing safety glass must be used in critical locations as follows.
Below is a list giving general view as to when safety glazing is required.
Safety glazing should be provided to any glass in a critical area.
Where this dimension is greater than 900mm glazing categorised as class a or b is required.